Example of plasma surface treatment
Valve cone Component part : Valve cone
Material : DIN 1.4581
(G-X7 CrNiMoNb 18)
Task : Improvement of wear resistance
Treatment : PulsPlasma®-Nitriding
Result : Surface hardness
>1000 HV
Nitriding depth 0.05 mm