Example of plasma surface treatment
Spiral roller for transport of wooden trunks Component part : Spiral roller for transport of wooden trunks
Material : DIN 1.5217 (20 MnV 6)
Task : Improvement of wear resistance
Treatment : PulsPlasma®-Nitriding
Result : Surface hardness 730 HV2
Nitriding depth 0,35 mm
Notice : Increasing of lifetime 3 times